ABB S500 series heavy-duty circuit breaker

Product Overview

The S500 series heavy-duty circuit breaker is a low-voltage electrical protection equipment launched by ABB, designed to cope with the increasing short-circuit current in low-voltage power grids, with high safety, reliability, and breaking capacity. Its core function is to protect circuits, motors, equipment, and systems from the effects of overload and short-circuit currents through thermal and/or electromagnetic trip functions.

The main features of this series of products include:

High rated breaking capacity, up to 30/50 kA

High rated operating voltage (400/690 VAC, 750 VDC)

Capable of energy and current limiting breaking, with extremely short breaking time

Optimized selectivity ensures that only the faulty part is disconnected in the event of a malfunction

Reliable switch and contact position indication

Compact size (compliant with DIN standards)

Rich accessories (such as undervoltage release, shunt release, auxiliary contacts, and signal contacts, etc.)

Widely applicable in various fields, including railways, commercial buildings, offshore platforms, ships, processing industries, and rail trams.

Main product types and applications

1. Circuit protection category

S500-B: Suitable for circuits that generate minimal or no surge current in power supply equipment (such as boilers, electric heaters, stoves).

S500-C: “Standard” miniature circuit breaker, suitable for powering electrical equipment (such as inductive devices, televisions, fluorescent lamps, gas discharge lamps) and sockets that generate surge currents.

S500-D: Suitable for circuits that supply power to electrical equipment that generates extremely high surge currents, such as transformers and capacitor banks, and can also serve as a protective device for upstream circuit breakers.

2. Motor protection category

S500-K: Used to protect single-phase and three-phase motors, can be installed in a fuse free motor control center (MCC), and the rated current can be adjusted.

S500-KM: Provides short-circuit protection for motors, combining the functions of contactors and thermal overload relays, with only electromagnetic trip function.

S500X-AG0084: As an alternative product to S500-KM, it is suitable for installation in high short-circuit current scenarios and needs to be used in conjunction with additional overload protection devices.

3. DC circuit protection category

S500UC-B: Used for circuits and electrical equipment in DC networks and DC powered vehicles, with a fixed rated current.

S500UC-K: Used for circuits and electrical equipment in DC networks and DC powered vehicles, with adjustable rated current.

4. Equipped with residual current protection

F500-C, F500-D: Combination circuit breakers with circuit protection characteristics and built-in residual current protection.

F500-K: A combination circuit breaker with motor protection features and built-in residual current protection.

DDA series: residual current protection device that can be installed by customers on S500 heavy-duty circuit breakers, suitable for sinusoidal AC residual current and pulse residual current in DC circuits.

Technical parameters

1. General parameters

Rated voltage: 400/690 VAC, 750 VDC

Rated insulation voltage: 690 VAC, 750 VDC

Rated breaking capacity (according to IEC 60947-2): 50 kA

Frequency: 50/60 Hz, can provide 16 2/3 Hz, 60-400 Hz according to requirements

Environmental temperature: -25 ° C…+55 ° C

Mechanical lifespan:>20000 switch cycles

Protection level: IP20

2. Special parameters for different types of products

Product Type Rated Current Range Tripping Characteristics

S500-B, S500-C, S500-D 6… 63A thermal release: 1.13… 1.45 xIn; Electromagnetic release: 3… 5 xIn (Type B), 5… 10 xIn (Type C), 10… 20 xIn (Type D)

S500-K 0.1… 45A thermal release: 1.05… 1.2 xIn; Electromagnetic release: 8… 14 xIn depending on the current

S500UC-B 6… 63A thermal release: 1.13… 1.45 xIn; Electromagnetic release: 5… 7 xIn (DC)

S500UC-K 0.1… 45A thermal release: 1.05… 1.2 xIn; Electromagnetic trip: 8… 14 xIn (DC) depending on the current

Selective and backup protection

Selectivity: In low-voltage distribution systems, when a short circuit occurs, two or more overcurrent devices connected in series should be selectively disconnected to ensure the continuity of power supply. The S500 heavy-duty circuit breaker has good selectivity compared to upstream circuit breakers due to its low passing energy and fast breaking ability.

Backup protection: If the short-circuit current at the installation point does not exceed 50/30 kA, the S500 heavy-duty circuit breaker can be installed with or without any size of upstream circuit breaker or backup fuse. If the short-circuit current exceeds its breaking capacity, the rated current of the upstream S500 circuit breaker shall not exceed the specified value.

Attachment

1. Factory installation accessories

Including switch neutral wire NA, separation neutral wire N, undervoltage release UA, shunt release AL, residual current release signal contact T10, etc.

2. Customers install accessories

Including auxiliary contact HK, signal contact SK, locking device, rotary driver, handle, busbar terminal, end cover, insulation terminal, flush mounting frame, terminal cover, middleware, etc.

Installation and Dimensions

Installation method: S500 circuit breaker is designed for snap fit installation on standard 35mm rails.

Size: The size of products varies depending on the type and number of poles, for example, the 2-pole F502 series has a width of 75mm, the 3-pole F503 series has a width of 100mm, and the 4-pole F504 series has a width of 125mm.

Safety distance: There are specific safety distance requirements between grounding components, insulation covers or wiring pipelines, and exposed live parts.

ABB PM665 3BDS005799R1 processor module

Basic information

Product ID: 3BDS005799R1

ABB model name: PM665

Product Description: Based on Power PC, equipped with redundant voter, high-speed link, and speed input processor module.

Product type: Central-Unit

Note: This product is exempt from the 2011/65/EU (RoHS) directive, based on Article 2 (4) (c), (e), (f), and (j), with reference to document 3BSE088609 (EU Declaration of Conformity for ABB Advance Master Process Control Systems).

Ordering and Customs Information

HS code: 853710, covering boards, panels, consoles, etc. equipped with two or more devices of item 85.35 or 85.36, used for electrical control or distribution, including instruments or equipment of chapter 90 and numerical control equipment (excluding switchgear of item 85.17), with a voltage not exceeding 1000V.

Customs tariff number: 85371091

Size and weight

Product net depth/length: 252mm

Product net height: 273mm

Product net width: 40mm

Net weight of product: 2.04kg

Environmental related information

RoHS Status: Compliant with EU Directive 2011/65/EU

WEEE category: not within the scope of WEEE

SCIP: ea0c62c6-ca6e-4d56-ba94-48c4d0c5b621 (Germany)

Classification

Control System Products – Control and Communication – AC 100- Processor Modules – PM665 Processor Modules – PM665 Processor Modules

Control System – Advant OCS with Master SW – Controller – Advant Controller 160- Advant Controller 160 Version 2.2- Central Unit (repeated list)

Safety specifications are generally applicable to control system handling. Instructions and warnings related to a specific subject or operation of the product.

The following norms must be strictly observed:

 must strictly comply with the technical specifications and typical applications of the product system

 Personnel training: Only trained personnel shall install, operate, maintain or repair the product system. must

Provide guidance and explanation of the situation in danger areas to these personnel.

 Unauthorized changes: Changes or structural changes to the product system may not be made.

 Maintenance responsibility: Must ensure that the product system is used only under appropriate conditions and in full fitness for use.

 Working environment: The user must meet the specified environmental conditions:

Safety regulation

The following safety provisions of EN 50110-1 shall be fully complied with when handling product systems (maintenance) :

1 Disconnect completely.

2 Secure to prevent reconnection.

3 Verify that the installation is complete.

4 Ground and short-circuit the device.

Warning: Only qualified maintenance personnel can remove and insert the module. In order to ensure the personal safety of the operator, before each pulling out or inserting, you must

Disconnect the power supply and ensure that there is no voltage on all terminals at the back, and the product is effectively grounded with the ground screw at the back.

Honeywell Fire Sentry SS2 Flame Detector

Product Overview

The Fire Sentry SS2 series is a globally outstanding multispectral digital photoelectric flame detector that utilizes leading UV/IR technology and has been successfully applied in numerous installation sites worldwide. This series of detectors can sense the radiation energy of ultraviolet (UV), visible light, and wideband infrared (IR) spectra, and can detect various types of open flames. It has a wide field of view and high sensitivity, while effectively avoiding false alarms.

Model and Features

SS2-A and SS2-AN

Multispectral detection: sensing ultraviolet, visible light, and WideBand IR ™。

Detection range: Can detect both hydrocarbon and non hydrocarbon fires.

Performance advantages: Wide field of view and day blindness, high sensitivity, with false alarm immunity, using a microprocessor based algorithm (FirePic) ™  And Tri Mode Plot ™), The working temperature range is wide, and the shell is explosion-proof. It has been verified in applications worldwide and is compatible with approved fire alarm panels.

SS2-AM and SS2-AML

Multispectral detection: equally sensitive to ultraviolet, visible light, and WideBand IR ™, Can detect both hydrocarbon and non hydrocarbon fires.

Outstanding features: Wide field of view and day blindness, high sensitivity, with false alarm immunity, using a microprocessor based algorithm (FirePic) ™  And Tri Mode Plot ™), The working temperature range is wide, the shell is explosion-proof, and the response speed to explosive fires is extremely fast.

Application scenarios

SS2-A and SS2-AN: Petrochemical facilities and refineries, combined power plants, aircraft hangars, silane gas storage facilities, gas turbines and power plants, gas compressor stations, etc.

SS2-AM and SS2-AML: ammunition production, explosive production, manufacturing of other explosive materials, silane and hydrogen storage facilities, and special application scenarios.

Operation mode

Powered by a standard 24V DC power supply, it can be connected to approved fire alarm panels or standard PLCs.

After power on, a self check will be performed, and the fault relay will reset to display no faults. The front LED will flash every ten seconds to indicate that the power is on.

The microprocessor analyzes the continuous spectral data stream from the sensor array, activates the alarm relay upon alarm, and stores all pre fire spectral data in non-volatile memory, FirePic ™  The data can be used to speculate on the cause of the fire.

Can be connected to standard control panels and PLCs to initiate alarm and mitigation processes as needed.

Technical specifications

General specifications for SS2-A and SS2-AN

Sensitivity: The detection distance for a 0.1 square meter (1 square foot) n-heptane fire is 18.2 meters (60 feet).

Response time: The response time to a 0.1 square meter (1 square foot) n-heptane fire at 18.2 meters (60 feet) is 2-5 seconds.

Field of view: 120 degree cone (60 degrees off-axis).

Spectral sensitivity: UV 185-260 nanometers, wideband infrared 0.7-3.5 micrometers, visible light 400-700 nanometers.

Input power supply: nominal 24V DC (20.5-34V DC).

Power consumption: Normal operation 56mA, alarm state 68mA.

Output relay: Fire alarm relay has NO and NC contacts, locked/non locked (factory set), usually powered off; The faulty relay has NO and NC contacts and is usually powered on; The rated value of relay contacts is 0.5A at 120V ac and 1.0A at 24V dc.

Working temperature: -40 ° C to 85 ° C (-40 ° F to 185 ° F).

Humidity range: 0-98% RH, no condensation.

Vibration: Complies with MIL.STD.810C standard.

Weight: 1.7kg (3.8 pounds) made of aluminum, 3.4kg (7.6 pounds) made of 316 stainless steel.

Shell: Copper free aluminum (content less than 0.4%) powder coating, compliant with NEMA4, NEMA4X-IP66, tamper proof, with integrated dual M25 or 3/4 “NPT conduit openings, provided with 316 stainless steel shell.

Electrical certification: ATEX, IECEX II 2 GD, etc.

Installation: Rotating bracket assembly (SM4- optional), made of 316 stainless steel material.

Warranty: Two years from the date of factory shipment.

General specifications for SS2-AM and SS2-AML

Sensitivity: The detection distance for a 0.1 square meter (1 square foot) n-heptane fire is 18.2 meters (60 feet).

Response time: The response time for explosive fires is 3.9 milliseconds.

The remaining parameters (field of view, spectral sensitivity, input power, power consumption, operating temperature, humidity range, vibration, weight, enclosure, electrical certification, installation, warranty) are the same as SS2-A and SS2-AN.

Honeywell Fire Sentry SS4 Fire and Flame Detector

Product Overview

The Fire Sentry SS4 series is an optoelectronic digital fire and flame detector that utilizes leading UV and UV/IR technologies, including models such as SS4-A, SS4-AS, and SS4-AUV. It has successfully operated in numerous installation sites worldwide, effectively detecting various types of fires and minimizing false alarms.

Characteristics of each model

SS4-A

Representing the world’s outstanding UV/IR photoelectric flame detector technology, it adopts a multispectral design that can sense the radiation energy of ultraviolet (UV), visible light, and wideband infrared (IR) spectra, and can detect all types of open flames.

To eliminate common false alarms that may occur with single UV, single IR, dual IR, or dual-mode UV/IR detectors, its FireLogic signal processing requires simultaneous evaluation of UV, visible light, and wideband IR radiation energy before alarm, optimizing fire alarms through real-time signal processing algorithms to almost eliminate false alarms.

SS4-AS

We optimized the detection of hydrogen, ethanol, methanol, and methane (natural gas) fires by processing UV, IR, and visible light (VIS) spectral ranges using reinforced day blind UV, quantum effect IR, and VIS sensors, which can respond to type A, B, and C open flames.

SS4-AUV

Representing leading UV optical flame detector technology, it only senses the radiation energy of the ultraviolet (UV) spectrum and is suitable for indoor applications without UV sources such as welding.

Application scenarios

Including petrochemical facilities and refineries, power plants, aircraft hangars, silane and hydrogen storage facilities, gas turbines and power plants, gas compressor stations, warehouses, semiconductor industry, etc.

Operation and Technical Specifications

Operation mode

Powered by a standard 24V DC power supply, it can be connected to approved fire alarm panels or standard PLCs. After power on, a self check will be performed, and the fault relay will reset to display no faults. The front LED will flash every ten seconds to indicate that the power is on.

The microprocessor analyzes the continuous spectral data stream from the sensor array, activates the alarm relay upon alarm, and stores all pre fire spectral data in non-volatile memory, FirePic ™  The data can be used to speculate on the cause of the fire.

As FS2000 ™  As part of the system, the SS4 series detectors use a four wire bidirectional RS-485 FireBus ™  Communicate with CM1-A controller.

Technical specifications

Sensitivity: The detection distance for a 0.1 square meter (1 square foot) gasoline fire can be adjusted between 18 meters (60 feet), 14 meters (45 feet), 9 meters (30 feet), and 4.5 meters (15 feet).

Response time: The response time to a 0.1 square meter (1 square foot) gasoline fire at 18 meters (60 feet) is 2-5 seconds.

Field of view: 120 degree cone (60 degrees off-axis).

Spectral sensitivity: UV 185-260 nanometers; SS4-A and SS4-AS also include wideband infrared 0.7-3.5 microns and visible light 400-700 nanometers.

Input power supply: nominal 24Vdc (20.5-34Vdc).

Power consumption: The relay version operates normally at 68mA and has an alarm state of 75mA; the analog version has an alarm state of 95mA.

Output relay: The fire alarm relay has NO and NC contacts, which can be switched between locked and non locked modes; The fire verification relay has NO and NC contacts, and the time can be adjusted between 0-30 seconds; The faulty relay has NO and NC contacts. The rated values of the relay contacts are 0.5A at 120Vac and 1.0A at 24Vdc (non inductive). During normal operation, the faulty relay is powered on while other relays are powered off.

Working temperature: -40 º C to 85 º C (-40 º F to+185 º F).

Humidity range: 10-98% RH, no condensation.

Weight: Stainless steel version 3.4kg (7.5 pounds); Aluminum version 1.8kg (4 pounds).

Shell: Copper free aluminum (content less than 0.4%) powder coating, compliant with NEMA4 (IP66), tamper proof, with integrated dual 3/4 “NPT conduit opening or optional M25, provided with stainless steel shell.

Certification: FM Class I Zone 1 and Zone 2, Groups B, C, and D; Class II, Zone 1 and Zone 2, Groups E, F, and G; Class III; ATEX, IECEx, etc. FMEDA complies with the safety requirements of IEC 61508.

Vibration: Meet or exceed MIL Spec 810 C method 514.2, curve AW.

Installation: Rotating bracket assembly.

Warranty: Two years from the date of factory shipment.

Output options: 0-20mA “source” output.

Honeywell FS7 Multi-Spectrum Fire and Flame Detector

Product Overview

The Fire Sentry FS7 is a multispectral digital photoelectric radiation infrared fire and flame detector designed specifically for semiconductor cleanroom fire protection applications. It includes the FS7-2173 photoelectric radiation fire detector and the FS7-2173-2RP (modular model), the latter of which features multispectral WideBand IR ™、 Near band IR and visible light band fire detection function. Among them, FS-2173-2RP is independent, and FS-2173 is connected to the control module for use.

Core Features

Multispectral detection: using multispectral digital photoelectric radiation infrared technology, covering visible light, near band IR, and wideband IR detection ranges.

Two level fire detection response: Provide intelligent two-level response for semiconductor wet table fires. Level 1 (Alert): Respond to small fires with a heat output of 3kW (equivalent to a 100mm diameter polypropylene pool fire) and allow time for the fire to self extinguish; Second level (Alarm): If the fire does not self extinguish and expands to the 13kW thermal energy threshold specified by Factory Mutual (equivalent to a 200mm diameter polypropylene pool fire), the second level response is activated.

Anti interference capability: not affected by false alarm sources, not affected by absorbent smoke, gas or chemical vapor, insensitive to background radiation energy of electric heaters and ovens, capable of detecting hydrocarbon and non hydrocarbon fires.

Durable design: Adopting a sturdy leak proof, heat sealed, acid resistant injection molded polypropylene shell, with a wide field of view (120 °) and RS-485 interface for digital communication, FirePic ™  The function can record digital fire characteristics with time and date stamps, and the built-in detector has automatic self checking function. The modular model design can operate independently.

Application scenarios

Clean room open area

Wet table working surface

Wet platform underground space (ventilation room)

Pumps and equipment behind the wet table area

Underfloor area

IPA station (only for modular models)

Product model details

FS7-2173

It needs to be used in conjunction with the Fire Sentry FS7-130-SX controller or FSWB control panel. The controller and control panel provide power to the detectors, monitor the status of all detectors, and communicate with the detectors through a digital RS-485 communication channel.

Standard 6m (20ft) cable connector, connected to the controller or control panel through self-locking connector and Fire Sentry junction box, easy to install and reduces wiring problems.

Each detector can store up to 6 FirePics with time and date stamps in non-volatile memory ™ (Pre event multispectral sensor array data), the controller and control panel can also store event history tables in non-volatile memory, including warning, alarm, and fault history with time and date stamps. FirePics can be retrieved from the controller or control panel ™  And the history of events.

FS7-2173-2RP (modular model)

Equipped with discrete relay output, designed as an independent detector that can interface with any approved fire alarm panel.

The microprocessor is equipped with digital signal processing algorithms to continuously monitor the circuit, and the sensors have built-in self checks to verify normal operation.

Requires an external 24VDC power supply, comes with a standard 6m (20ft) tail cable, and can store up to 6 FirePics with time and date stamps in non-volatile memory ™  With 200 events, FirePics can be retrieved using the Fire Sentry FS7 interface suite and Windows based PC software ™  And the history of events.

Technical specifications

Project/Details

Field of view: 120 ° horizontally and vertically

Response time: Warning: For a 100mm (4-inch) diameter polypropylene pool fire (3kW), respond within 5 seconds; Alarm: Response within 5 seconds for 200mm (8 inches) diameter polypropylene pool fire (13kW)

Spectral sensitivity: visible light: 400-900 nanometers; Near band IR: 0.7-1.1 micrometers; Wide band IR: 0.7-3.5 microns

Working voltage: Controller: nominal 24VDC (18-28VDC) – stabilized voltage; Detector: 10-12VDC from FSC controller

Power consumption: Working: 55mA at 24VDC nominal (controller)+30mA at 12Vdc per detector; Alarm: 80mA at 24VDC nominal

Output relay: Warning: SPST, normally open, power off; Fire alarm: SPDT (normally open/normally closed) – power off/on, locked/unlocked; Fault: SPST (normally open) – normally powered on, locked/unlocked; Contact rating: 1 ampere at 24VDC

Communication: RS-485, FireBus II

Visual indication: Red LED

Temperature range: Operating: 0 º C to 70 º C (32 º F to+158 º F)

Humidity range: 10-90% relative humidity, no condensation

Shell material: dustproof, waterproof, heat sealed injection molded polypropylene

Shell type: IP67

Certification: FM 3260, FM 3600, FM 3611, CSFM Certification (California Fire Commissioner)

Transport weight: 1.4kg (3lbs.)

Installation: Chassis installation sliding bracket

Warranty: Two years from the date of shipment

image.png

Honeywell FS10 Fire Detection Systems For Liquid Paint Spray

Product Overview

Fire Sentry FS System 10 ™  FS10-R is a fire detection/process control system designed specifically for automatic electrostatic powder spraying booth, belonging to multispectral digital photoelectric infrared fire detectors. It protects electrostatic powder spray booths worldwide, achieving millions of hours of safe operation and ensuring process safety 24/7.

Core Features

Multispectral detection: Using multispectral digital optoelectronic infrared technology, it has the ability to detect visible light, near-infrared, and wideband infrared.

Two level response mechanism: Unique two-level ALERT (warning) and FIRE ALARM (fire alarm) response, issuing a warning for gun “fireball” type fires first, and if the fire persists, issuing a fire alarm within 4-5 seconds.

Anti interference ability: not affected by false alarms caused by arc or corona discharge, insensitive to background radiation energy such as paint heaters, not affected by smoke absorption or paint solvent mist in liquid paint spraying booth, able to detect paint, powder or oil residue through the detector lens.

Intelligent function: Built in automatic “through the lens” self-test function, equipped with RS-485 interface for digital communication, FirePic ™  Retrievable pre fire data records, SnapShot ™  It can dynamically display the content detected by the detector in graphics.

Application scenario (indoor use only)

Liquid paint spraying line

Aerosol filling

Powder coating booth

Curing Oven

Product Details

Fire Sentry FS System 10 ™

Design purpose: Designed specifically for liquid and powder coating applications, it is a high-speed detection solution with process control capabilities. It can quickly detect flames, initiate the shutdown of the electrostatic coating process within milliseconds, and prevent the spread of fire.

Controller configuration: There are two configurations: wall mounted controller and card type controller. The wall mounted controller is an independent system installed in a NEMA 12 enclosure with an LCD display and LED status lights, and includes three 10 ampere mechanical relays for turning off paint flow, static electricity, and conveyor belts.

Data storage and communication: The detector reports real-time event history and fire technology data, stored in the non-volatile memory of the controller, FirePic ™  And SnapShot ™  Data can be downloaded from the RS-232 port of the controller via a PC, and each controller can be connected to 1 or 2 detectors.

Fire Sentry FS10-R Unitised

Design Basis: Based on Fire Sentry FS System 10 ™  Design with independent operational capability.

Performance features: Its WideBand IR ™、 Near band IR and visible light sensors combined with advanced signal processing provide optimal performance, high-speed fire response, and optional factory sensitivity settings and alarm outputs, providing an enhanced fire detection and safety solution for the coating industry.

Interface method: Designed to be used in conjunction with any approved fire alarm panel, the interface with the fire alarm panel is achieved through ALARM, ALERT, and FAULT relays of the detector.

Technical specifications

FS10 wall mounted controller specifications

Shell: NEMA 12 painted steel shell with welded seams, door gasket, key lock.

Display and indicator: 4 status LEDs (fault, fire early warning, warning, alarm), 1 LCD display screen.

Input power supply: There are different options such as 120VAC and 240VAC, allowing for ± 10% fluctuation.

Power consumption: The 120VAC option is rated at 0.22 amperes (25 watts), while the 240VAC option is rated at 0.11 amperes (25 watts).

Output signal relay: including fire early warning, warning, fire alarm, fault and other relays, with a rated contact value of 1 ampere at 24VDC.

Process shutdown relays: 3 SPDT relays with contact ratings of 10 amperes at 120VAC.

Controller temperature: 0 ° to+50 ° C (+32 ° to+122 ° F).

FirePic ™: There are a total of 6, each lasting 8 seconds.

Detector (FS10 related) specifications

Sensitivity: 4.57 meters (15 feet).

Response time: 0.3 seconds for warning (for “fireball” type fires), 0.5 seconds for early warning of fires, and 4 seconds for fire alarm (if the fire persists).

Field of view: 90 ° (horizontal and vertical ± 45 °).

Weight (aluminum): 1.7 kilograms (3.8 pounds).

Working temperature: -40 º to+85 º C (-40 º to+185 º F).

Shell: Copper free powder coated aluminum or optional 316 stainless steel, compliant with NEMA 3, 4, and 4X standards.

Certification: Explosion proof; Class I, Zone 1 and Zone 2, Groups B, C, and D; Class II, Zone 1 and Zone 2, Groups E, F, and G; Class III; FM and CE certification.

Spectral sensitivity: visible light 400-700 nanometers, near band IR 0.7-1.1 micrometers, wide band IR 0.7-3 micrometers.

Conduit inlet: Two three-quarters “NPTs.

Dimensions: Diameter 122.17 millimeters (4.81 inches), depth 118.11 millimeters (4.65 inches).

Installation: Optional rotating bracket component.

Warranty: Two years from the date of shipment.

FS10-R General Specification

Sensitivity: For a 0.3 square meter (1 square foot) fire, the factory sets it to 13.7 meters (45 feet) and 9.1 meters (30 feet) * (note: detectors set to 13.7 meters (45 feet) sensitivity have no warning/fire early warning output).

Response time: 0.3 seconds for warning (for “fireball” type fires), 1 second for early fire warning, and less than 5 seconds for fire alarm (if the fire persists).

Field of view: 90 ° (horizontal and vertical ± 45 °).

Input power supply: nominal 24VDC (18-32VDC) – regulated.

Power consumption: Normal 85mAh (typical value), alarm 120mAh (typical value).

Output relay: SPST for warning/early warning, normally open; The fire alarm is SPST, normally open; The fault is SPST, constantly open without power supply, with a rated contact value of 1 ampere at 24VDC.

Normal operation: The faulty relay is powered on and not locked; All other relays are powered off; Fire and warning relays can be selected to be locked or non locked.

Working temperature: -40 º C to+85 º C (-40 º F to+185 º F).

Humidity range: 0% to 90% relative humidity, no condensation.

​FS10 Card Controller Specification

Shell: NEMA 1 steel shell.

Indicator: 4 status LEDs, corresponding to normal operation, warning, fire early warning (FEW), fire alarm, and fault status.

Input power supply: 24V DC (+10/-15%).

Power consumption: 65 milliamps, nominal 1.6 watts.

Output signal relay: There are multiple models, and different models have different relay configurations.

FirePic ™: There are a total of 6, each lasting 8 seconds.

Honeywell Model FS20X Multi-Spectrum Fire and Flame Detector

Product Overview

FS20X is the latest generation of high-tech multispectral (UV/dual IR/VIS) fire and flame detectors, belonging to the FSX series of advanced technology photoelectric flame detectors. It is based on the highly successful and reliable SS4 detector development, achieving a huge leap in integrating infrared and ultraviolet sensing technologies, and has a validated ultraviolet sun blind sensor. Compared with traditional UV/IR detectors, FS20X responds faster to fires over a wider temperature range without false alarms, and has a longer detection range.

Core Features

Advanced sensing technology: using patented WideBand IR ™  The combination of infrared technology and ultraviolet technology, equipped with visible light sensors to optimize false alarm elimination, and a validated ultraviolet sun blind sensor.

Performance parameters: Detection range exceeding 60 meters (200 feet) (for a 0.1 square meter (1 square foot) heptane reference flame under extremely high sensitivity settings), field of view at a 90 ° horizontal cone (off-axis ± 45 °), selectable detection sensitivity (extremely high (60 meters), high (45 meters), medium (30 meters), low (15 meters)).

Intelligent function: Dual microprocessors ensure high-level fault safe operation and fast and reliable performance; Equipped with a real-time clock that can accurately record event times; FirePic ™  Can store up to 6 pre fire event data; Event logs can record up to 200 events with dates and timestamps.

Communication and output: Built in RS-485 ModBus communication function, non isolated 4-20mA analog output (sink or source), with alarm, fault, and fire verification relays.

Other features: automatic optical path and electronic self-test; The patented electronic module is used for component protection and adopts plug-in termination for easy on-site installation; There are two 25mm conduit inlets or two three-quarters “NPT inlets; Low power consumption, high resistance to radio frequency interference and electromagnetic interference; Obtained multiple certifications such as FM, ATEX/IECEx, INMETRO, CU-TR, etc., meeting SIL 2 requirements, optional certification to EN54-10:2002, with FM 3260 performance.

Advantages and Applications

advantage

Capable of detecting hydrocarbon and non hydrocarbon fuel fires under all environmental conditions, with a wide operating temperature range, unaffected by arc welding, and good false alarm elimination effect.

Low maintenance, stable operation, fault diagnosis, real-time graphics (RTGs) display, and FirePics download can be performed through PC software and interface module (FSIM) ™  And event logs, suitable for various application scenarios.

Application scenarios: including refineries and oil production facilities, offshore platforms, turbine/compressor casings, acetylene processing and storage facilities, oil and gas pipelines and pumping stations, LNG/LPG loading and unloading facilities, natural gas and CNG plants, ethanol, methanol and IPA production and storage facilities, crude oil and gasoline storage and oil depots, aircraft hangars, hydrogen plants and storage facilities, paint and solvent storage facilities, chemical production, storage and loading and unloading facilities, power plants, silane gas storage facilities, etc.

Technical specifications

Project, details

Response time: 3-5 seconds for a 0.1 square meter (1 square foot) n-heptane flame at a distance of 30 meters (100 feet); Response time of 3-10 seconds for a 0.1 square meter (1 square foot) n-heptane flame at a distance of 60 meters (200 feet)

Spectral sensitivity: UV: 185-260 nanometers; Visible light: 400-700 nanometers; Near band infrared: 0.7-1.1 micrometers; Wide band infrared: 1.1-3.5 microns

Working voltage: nominal 24 Vdc (18-32 Vdc) – stabilized voltage

Power consumption operation: 85 mA at 24 Vdc nominal; alarm: 135 mA at 24 Vdc nominal; heater: additional 155 mA (note: heater turns on at -17 º C (0 º F))

Output relay: Fire alarm: SPDT (NO/NC) – power-off/power on, locked/non locked; Fault: SPST (NO) – Power off/on, locked/unlocked; Auxiliary: SPDT (NO/NC) – power-off/power on, locked/unlocked; Contact rating: 1 ampere at 24 Vdc

Analog output: 0-20 mA stepped – source or sink can be selected by the user

Loop resistance 50-400 ohms

Communication: One of the following can be selected by the user: RS-485, ModBus protocol; RS-485,FireBus II; RS-485 dedicated (optional); HART, Optional plugin module (not applicable to EN54-10 devices)

Visual indicator: Green LED: Power supply; Red LED: Alarm; Yellow LED: Fault

Temperature range: Operating: -40 to+85 º C (-40 to+185 º F); Storage: -55 to+110 º C (-67 to+230 º F)

Humidity range: 5-98% relative humidity, no condensation

Vibration: reaching or exceeding MilSpec 810C method 514.2, curve AW12

Wiring: 2.5 mm ² (14 AWG) to 0.326 mm ² (22 AWG); Recommend using shielded cables

Conduit inlet: Standard: Two M25 or two three-quarters “NPT

Shell material: Copper free powder coated aluminum or 316 stainless steel

Shell type: 4X, IP66, and NEMA 4

Certification: FM, ATEX/IECEx, INMETRO, CU-TR, China EX and other certifications, SIL rating: FMEDA can be provided upon request, FS20X certification is 1175a/01 (LPCB), CPR 0832-CPR-F0515

Transportation weight: Aluminum: 1.6 kg (3.6 lbs); Stainless steel: 3.2 kg (7 lbs)

Installation: Optional rotating bracket component

Warranty: Three years from the date of shipment

Honeywell Model F24X QuadBand ™  Triple IR Fire

Product Overview

The Fire Sentry FS24X is the latest generation of high-tech multispectral triple infrared (IR/IR/IR/visible light) flame detector, belonging to the FSX series of advanced technology photoelectric fire detectors. It adopts patented WideBand IR ™、 WideBand 4.3-micron IR ™  Visible light detection technology has achieved a huge leap in flame detection. The complex software algorithms and dual microprocessors ensure the highest flame detection performance while optimally eliminating false alarms.

Core Features

Patent technology: WideBand IR with patented technology ™  Technology Electronic Frequency Analysis ™  The technology and Electronics Module technology used to protect components have improved detection performance and reliability.

Detection capability: Visible light sensors help optimize false alarm elimination; Selectable detection sensitivity; The field of view has a 110 ° cone of view (there are also 90 ° cone models).

Performance guarantee: Dual microprocessors ensure reliable performance; Real time clock can accurately record event time; FirePic ™  Capable of storing pre fire event data; The event log has a date and timestamp.

Communication and output: equipped with RS-485 ModBus communication function; Non isolated 4-20mA analog output (sink or source); There are alarm, fault, and fire verification relays.

Other features: automatic optical path and electronic self-test; Easy plug-in termination and on-site installation; Two inlet ports for 3/4 “NPT conduits; Low power consumption; High resistance to radio frequency interference and electromagnetic interference; Obtained multiple certifications such as FM, ATEX, CE mark, etc., meeting SIL 2 requirements. FS24X-9 option has passed EN54-10:2002 certification and has FM 3260 performance.

Advantages and Applications

advantage

Capable of detecting hydrocarbon and non hydrocarbon fuel fires under all environmental conditions.

Users can choose the output method; Wide working temperature range; The false positive elimination effect is good.

Low maintenance and stable operation; Fault diagnosis, real-time graphics (RTGs) display, and FirePics download can be performed through PC software and interface module (FSIM) ™  And event logs.

Suitable for various application scenarios; Easy replacement of electronic modules; There are test lights available for manual testing.

Application scenarios: including refineries and oil production facilities, offshore platforms, turbine/compressor casings, oil and gas pipelines and pumping stations, LNG/LPG loading and unloading facilities, natural gas and CNG factories, ethanol, methanol, and IPA production and storage facilities, crude oil and gasoline storage and oil depots, aircraft hangars, paint and solvent storage facilities, chemical production, storage, and loading and unloading facilities, power plants, etc.

Technical specifications

Project/Details

Field of view: FS24X-9: 90 ° cone, off-axis ± 45 °; FS24X-2: 110 ° cone, off-axis ± 55 °

Sensitivity: switchable options: extremely high (200 feet), high (150 feet), medium (100 feet), low (50 feet)

Response time: 3-5 seconds for a 1 square foot n-heptane flame at a distance of 30 meters (100 feet); Response time of 3-10 seconds for a 1 square foot n-heptane flame at a distance of 60 meters (200 feet)

Spectral sensitivity: visible light: 400-700 nanometers; Near band infrared: 0.7-1.1 micrometers; Broadband infrared: 1.1-3.0 microns, 3.0-5.0 microns

Working voltage: nominal 24 Vdc (18-32 Vdc) – stabilized voltage

Power consumption operation: 56 mA at 24 Vdc nominal; alarm: 106 mA at 24 Vdc nominal; heater: additional 155 mA (note: heater turns on at 0 º F (-17 º C))

Output relay: Fire alarm: SPDT (NO/NC) – power-off/power on, locked/non locked; Fault: SPST (NO) – Power off, locked/unlocked; Auxiliary: SPDT (NO/NC) – power-off/power on, locked/unlocked; Contact rating: 1 ampere at 24 Vdc

Analog output: 0-20 mA stepped – source or sink can be selected by the user

Loop resistance: 50-400 ohms

Communication: One of the following can be selected by the user: RS-485, ModBus protocol; RS-485,FireBus II; HART, Optional plugin module (not applicable to EN54-10 devices)

Visual indication: Green LED: Power supply; Red LED: Alarm; Yellow LED: Fault

Temperature range: Operation: 110 ° Field of view FS24X: -40 º F to+185 º F (-40 º C to+85 º C); 90 ° field of view FS24X: -60 ° C to+85 ° C (-76 ° F to+185 ° F); Storage: -67 º F to+230 º F (-55 º C to+110 º C)

Humidity range: 5-98% relative humidity, no condensation

Vibration: reaching or exceeding MilSpec 810C method 514.2, curve AW12

Wiring: 14 AWG to 22 AWG; Recommend using shielded cables

Conduit inlet: Standard: Two M25 or two three-quarters “NPT

Shell material: Copper free powder coated aluminum or 316 stainless steel

Shell type: IP66 and NEMA 4&4X

Certification: FM, ATEX/IECEx, INMETRO, CU-TR and other certifications, SIL rating: FMEDA can be provided upon request, FS24X-9 certification is 1175a/02 (LPCB), CPR 0832-CPR-F0516

Transportation weight: Aluminum: 1.6 kg (3.6 lbs); Stainless steel: 3.2 kg (7 lbs)

Installation: Optional rotating bracket component

Warranty: Three years from the date of shipment

Honeywell Searchline Excel Cross Direct Infrared

Product Overview

Searchline Excel Cross Direct is developed based on mature open circuit design, specifically designed to meet the monitoring needs inside HVAC ducts and turbine casings. It is a reliable infrared open circuit gas detector suitable for ducts. It can provide the highest response speed with a low alarm set point over a wide temperature range, complementing other system gas protection devices such as toxic gas detection, and providing fast and effective protection for gas entering ventilation ducts.

Application scenarios and core advantages

Application scenarios: including control rooms, personal shelters, turbine casings, etc.

Core advantages:

Fast response speed, able to provide early warning; High sensitivity, allowing for setting low alarm points.

The design that does not require alignment makes installation simple; Strong tolerance to pipeline bending and vibration, ensuring continuous operation of the system.

Built in functional gas testing device for easy system inspection; Anti pollution optical components reduce unplanned maintenance needs.

Not affected by catalytic toxins, it can work in an inert environment.

Technical specifications

Project/Details

Detectable gas calibration: methane (a gas mixture with methane as the main component (>70%) and the rest as C ₂ – C ₆ hydrocarbons)*

Detection range: 0-100% LEL

Minimum alarm threshold: 20% LEL (pipeline width>0.5 to 2.5m); 10% LEL (pipeline width>2.5 to 5m)

Response speed: T90<1 second

Output signal: Over range: 21mA; Warning: 3mA; Beam blocking: 2.5mA; Suppression: 2mA; Fault: 0mA; RS485 serial link

Digital output: Modbus RS485 multipoint (using DX100 (M) or XNX universal transmitter with Modbus option)

Working temperature: Environmental temperature: -40 ° C to+50 ° C (-40 ° F to 122 ° F); The maximum internal temperature of the pipeline can reach 60 ° C (140 ° F), but the external ambient temperature of the transmitter and receiver units must be within the working range; For high-temperature applications, please contact Honeywell Analytics

Working humidity: 0-99% (no condensation)

Work pressure: 91.5-105.5 kPa (without compensation)

Repeatability: 5.0% LEL (pipeline width<1 meter); 2.5% LEL (pipeline width>1 meter)

Preheating time:<1 hour (completely stable)

Power supply equipment: 18 to 32V DC; Heating reflector: 18 to 28V DC

Power consumption device: maximum 13W; heating reflector: rated as 6W at 24VDC

Shell material: 316 stainless steel

IP rating: IP66 and IP67

Weight: transceiver 13kg; reflector plate: 5kg (pipe width>0.5m to 2.5m), 10kg (pipe width>2.5 to 5.0m)

EMC standard: EN50270

Safety certification: ATEX, IECEx, UL and other certifications, specific certification information may vary depending on the components such as transmitter, receiver, heating plate, etc

Communication and installation related

Communication function: Can be combined with XNX universal transmitter kit, standard equipped with local HART ®  Ports and HART via 4-20mA ®, Can be accessed through the XNX user interface or compatible HART ®  Configure with handheld interrogator; In permitted applications, the SHC-1 handheld interrogator and SHC-1 protective device module can be used for invasive connections. The multi-point Modbus function can save installation and wiring costs, and the bidirectional digital communication protocol allows configuration, warning, and fault diagnosis information to be transmitted back to the control room, reducing maintenance costs.

Installation composition: The path range is 0.5m-5m, mainly including heated retroreflector, installation plate, installation unit, transmitter, receiver, conduit, junction box, etc.

Honeywell Searchline Excel Infrared Open Circuit Gas Detector

Product Overview

Searchline Excel is the world’s best-selling infrared open circuit gas detector, with over 25000 units installed in various challenging industrial applications. From the Arctic Circle to the deserts of the Middle East, it has always been the preferred product for customers and has become a standard configuration in the oil, gas, and petrochemical industries, meeting their demanding needs.

Application scenarios: including offshore platforms and vessels (FPSOs), downstream chemical processing plants, natural gas transportation and pipelines, large storage areas and buildings, perimeter inspections, etc.

Product Evolution: Honeywell Analytics launched the original Searchline in 1987, pioneering the design of open circuit infrared combustible gas detectors. Searchline Excel was launched in 1998 and became an industry standard through continuous improvement and high-quality manufacturing and control processes. It is often used in conjunction with Searchpoint Optima Plus as the primary combustible gas detector and auxiliary combustible point detector.

Core advantages and characteristics

Performance advantages

By using a dual bandpass filter, it can fully compensate for various fog, rain, and/or mist interferences.

100% unaffected by the sun, can work normally under partial shading conditions, and has strong anti vibration ability.

Radial symmetrical and bonded window heating, with good low-temperature performance; Coaxial optical systems provide the best performance and resistance to partial occlusion in their class.

Full temperature compensated solid-state detector with low power consumption under all conditions, equipped with a simple “locking” alignment tool, without the need for additional “software alignment”.

The telescope is designed with higher power and sturdiness, and can be equipped with Modbus RS485 multi-point output. It has obtained FM hazardous area and performance certification.

Advantages of open circuit gas detection: As a supplement to point detectors, it has reliable combustible gas detection (verified through use), wider coverage (most likely to detect any leaks), extremely fast response speed, fail safe (no unexposed fault modes, no possibility of gas path blockage), less critical detector position, can indicate the magnitude of danger, simple setup and debugging, and can replace multiple point devices.

Unique technological design

Patent optical design: It is the only solution that can fully address all challenges of open circuit combustible gas detection, using patented dual bandpass filters that can operate accurately and reliably in all weather conditions without relying on software masks that may affect gas detection capabilities.

Coaxial optical design: The unique coaxial optical design makes it the only open circuit gas detector that can operate normally under partial shielding conditions without generating false alarms, while non coaxial instruments may experience false alarms due to differential attenuation.

True Alignment System: Good installation is the key to achieving optimal performance for open circuit gas detection systems. This system can achieve precise alignment without the need for software based alignment tools for further adjustments. During installation, a telescope is used to visually inspect the path to ensure there are no physical obstacles.

Accessories and Communication

Main accessories: including XNX universal transmitter (providing local display and enhanced interface options such as relays and modern digital communication, including HART) ®、 Modbus and Foundation Fieldbus ™)、 Unique and validated telescope installation mechanism (with simple engagement and locking mechanism, three-point installation reference to ensure true alignment, and adjustable line of sight to the most convenient position), etc.

Communication function: Can be combined with XNX universal transmitter kit, standard equipped with local HART ®  Ports and HART via 4-20mA ®, Can be accessed through the XNX user interface or compatible HART ®  Handheld interrogator configuration; In permitted applications, SHC-1 handheld interrogator and SHC-1 protective device module can be used for invasive connection with Searchline Excel. The multi-point Modbus function can significantly save installation and wiring costs, and the bidirectional digital communication protocol allows configuration, warning, and fault diagnosis information to be transmitted back to the control room, reducing maintenance costs.

Technical specifications

Project/Details

Detectable gases: methane, ethane, propane, butane, pentane, ethylene, propylene, butadiene

Range 0 to 5 LEL. m

Recommended alarm setting: (low) 1.0 LEL. m; (Height) 3.0 LEL. m

Path length: Short distance 5m to 40m (15ft to 130ft.), medium distance 40m to 120m (130ft to 390ft.), long distance 120m to 200m (390ft to 650ft.)

Response speed: T90 less than 3 seconds (under normal operating conditions)

Output signal: 4-20mA (maximum loop resistance of 600 ohms; Provide source and sink) and RS485, 21mA over range, 4-20mA normal operation (0 to 5 LEL. m), 3mA (1) optical components dirty, 2.5mA (1) beam blocked, 2mA (1), 0mA fault

Digital output: Modbus RS485 multipoint. Use DX100 (M) or XNX universal transmitter with Modbus option

Working humidity: 0 to 99% RH (non condensing)

Work pressure: 91.5 to 105.5 KPa (915 to 1055 mbar) (without compensation)

Preheating time: less than 5 minutes (operable), or less than 1 hour (completely stable)

Power supply: 18V to 32VDC

Power consumption short-range transmitter: 3.5W/5.0W * maximum. Medium to long distance transmitter: 10W/13W * maximum. Receiver: 8W maximum.

Shell material: 316 stainless steel

Weight (including installation bracket): Short distance transmitter: 3.5kg, medium to long distance transmitter: 7kg, receiver: 3.5kg

Vibration 2 to 60Hz, maximum peak to peak amplitude 1mm

Alignment tolerance: short distance ± 0.5 º (at 40m ±~35cm), medium distance ± 0.5 º (at 120m ±~104cm), long distance ± 0.5 º (at 200m ±~170cm)

EMC standard: EN50270

Performance certification: FM performance certification

Safety certification: ATEX, UL, CSA, FM and other certifications

IP rating: IP66 and IP67

Installation Options

Installation options: Provides multiple installation configurations to meet the different connection requirements of hazardous and safe areas, such as connecting with controllers, DCS/PLC, SCADA systems, etc. It supports communication methods such as 4-20mA and Modbus, and can achieve redundant 4-20mA signal transmission, local invasive/non-invasive inquiry, remote status transmission, and other functions.